Medical Device Cybersecurity Hub
Moraph software. The Medical Device Cybersecurity Hub keeps one inventory of the connected medical devices in your hospitals, built from the exports of your clinical engineering system and network discovery tools. It matches each device to the published vulnerabilities and manufacturer advisories your team records or loads, tracks patch status and compensating controls, and routes remediation and risk-acceptance decisions to the right people. Clinical engineering, security and clinical departments work from the same record, with the evidence kept for auditors and your risk committee.
Raise a ticket about Medical Device Cybersecurity HubTroubleshooting guide (sign in to read)Product documentation
Critical incident? Raise an S1 ticket: support staff are emailed when you raise it, with the ticket marked critical. Check Moraph Status for incidents already under way.
What Moraph Support handles
- Access problems, errors and unexpected behavior in the Hub workspace
- CSV loads and Work API integrations from the CMMS, network discovery tools and advisory sources failing or not updating records
- Work API keys, scopes and integration errors
- Help configuring record types, fields, stages and allowed moves
- Reports and exports that fail or show unexpected results
What goes elsewhere
- Patching devices or validating patches, which go to the device manufacturer and your clinical engineering team
- Network access control, segmentation and discovery tool faults, which go to your network team or the tool's vendor
- Decisions on risk acceptance and clinical risk, which belong to your security leader and risk committee
Choosing a severity
| Severity | Examples for Medical Device Cybersecurity Hub |
|---|---|
| S1 Critical A production service is down or unusable, data may be at risk, or a security incident is under way, and there is no workaround. |
|
| S2 High A production service is badly degraded or an important function is failing, and the workaround is poor or temporary. |
|
| S3 Normal Something is not working as it should, but there is a reasonable workaround or the impact is limited. |
|
| S4 Low A question, a minor problem, a request for information or a change that can be planned. |
|
You choose the severity. Moraph’s support staff are emailed when a ticket is raised, an S1 ticket marked critical, and handle tickets as soon as they can. Moraph doesn’t promise a response or resolution time.
Before you raise a ticket
- Check whether the problem affects one device or record, or every record of that type
- Check the product's Activity for recent configuration changes
- Check recent calls under Work API keys for errors if an integration is involved
- Confirm the source system (CMMS, discovery tool or advisory feed) is up and sending data
- Try again in another browser or a private window to rule out a local issue
What to include in the ticket
- The record references involved, such as DEV-, VUL-, REM- or RSK- references
- The integration or feed name and the time it last worked
- The exact error message and the time it appeared
- The Work API key name, never the key itself
- What you expected to happen and what happened instead
- Screenshots with any personal or patient information removed
Don’t include passwords, secrets or full records of patients, customers or citizens. If we need data like that, we will arrange a secure way to receive it.
Common problems and fixes
A new advisory produced no findings
Likely cause: Affected devices have no model or software version recorded, so they cannot be matched.
What to do: Filter the device inventory or the reconciliation queue for devices with no software version, complete them from the CMMS or discovery data, then choose Match against the inventory again on the vulnerability.
The same device appears twice
Likely cause: Network discovery saw the device before the CMMS record existed, or the asset tag differs between sources.
What to do: Open the extra device and use This is a duplicate of another device to merge it into the record kept; it closes as Duplicate or not a device.
A remediation can’t be moved to Patched
Likely cause: No installed version is recorded, or the installed version is still in the vulnerability’s affected versions.
What to do: Use Record patch applied with the version now on the device; check the vulnerability’s affected versions if it is refused.
A device owner cannot see their devices
Likely cause: The Hub has three roles (viewer, user, product administrator); there is no per-department role, and the owning department on the devices may not match.
What to do: Ask your organization’s administrator to check People and access, then use the Department device risk report filtered to their department.
The CMMS feed stopped updating devices
Likely cause: The Work API key used by the feed was revoked because its owner lost the Product administrator role.
What to do: A revoked key can’t be rotated. Create a new key as a current Product administrator, deploy it and check recent calls under Work API keys.
Remediation tickets are not created in the service desk
Likely cause: The integration key lacks a scope, or the Remediation is not in a stage your integration raises tickets for.
What to do: Check the key’s scopes under Work API keys and the agreed stages, then move a test Remediation to confirm.
A risk acceptance expired without review
Likely cause: The review task raised before expiry was unassigned or not acted on.
What to do: Assign acceptances to the security leader, and use the risk acceptance register filtered to expiries within 30 days.
Changes made by a colleague appear next to mine when saving
Likely cause: Someone else saved the same record while you were editing it.
What to do: Review the flagged fields you both changed, keep the correct values and save again; nothing has been overwritten.